Pipe friction loss calculator
Friction loss here is the Hazen-Williams head for the pipe you describe, converted to PSI by dividing feet by 2.31. The coefficient C is 150 for PVC and PEX, 120 for galvanized, and 130 or 140 for copper. Fittings are added as equivalent feet of the same pipe. The result is pressure lost along that run. It is not a pump recommendation, and it does not add vertical lift.
The arithmetic runs in your browser. The entries are not sent to a server to be calculated. Vertical lift belongs on the well and booster size calculator, which uses 0.433 PSI per foot. 2.31 feet per PSI on this page is the matching conversion the other way.
How the numbers are calculated
Head in feet of water uses the Hazen-Williams form. Q is gallons per minute, d is inside diameter in inches, L is total feet, and C is the coefficient:
Head feet = 0.2083 × (L / 100) × (100 / C)^1.85 × Q^1.85 / d^4.87
PSI = head feet / 2.31
Velocity, feet per second = 0.4085 × Q / d^2
0.2083 per 100 feet is the constant in PPI TR-14. That report prints exponents 1.852 and 4.8655, for thermoplastic pipe at C = 150. This page uses 1.85 and 4.87, equation 12 of the AWWA C904 committee report, because those exponents reproduce that report's Table 4 when the feet are divided by 2.31. On the rows below, the PPI exponents stay inside the table's rounding. Equation 12 is also the source of the divide-by-2.31 step. 2.31 feet of water per PSI is the same factor the booster calculator uses, from the Engineering Toolbox head-and-pressure page. Velocity is equation 13 of the same AWWA report. This page shows velocity and does not apply a speed limit.
C values:
- PVC: 150. Galvanized iron: 120. Copper: 130–140. Engineering Toolbox Hazen-Williams coefficients. Copper is a range, so the form makes you pick 130 or 140. 130 is the higher loss.
- PEX: 150, from the AWWA C904 committee report. The Engineering Toolbox table does not name PEX. Its "plastic" row is 130–150, and this page does not use that row for PEX.
There is no single published table in these sources that lists PVC, PEX, copper, and galvanized on one line. The four values above are the two sources named.
Inside diameter
| Nominal size | PVC | PEX | Copper Type L | Galvanized |
|---|---|---|---|---|
| 1/2 inch | 0.622 | 0.475 | 0.545 | 0.622 |
| 3/4 inch | 0.824 | 0.671 | 0.785 | 0.824 |
| 1 inch | 1.049 | 0.865 | 1.025 | 1.049 |
| 1-1/4 inch | 1.380 | 1.055 | 1.265 | 1.380 |
| 1-1/2 inch | 1.610 | 1.245 | 1.505 | 1.610 |
| 2 inch | 2.067 | 1.629 | 1.985 | 2.067 |
- PVC Schedule 40 is outside diameter minus twice the minimum wall, from the Engineering Toolbox ASTM D1785 table. That is the largest bore. A thicker wall is a smaller bore and a higher loss.
- Galvanized uses the Schedule 40 steel inside diameter from the Engineering Toolbox ASME B36.10 table. That table does not list a zinc thickness, so none is subtracted.
- Copper Type L is the nominal inside diameter in Copper Tube Handbook Table 14.2b.
- PEX is the average inside diameter in AWWA C904 Table 3, for a flow estimate. It is not the diameter of an insert fitting.
Fittings
Each fitting adds the equivalent feet below, and that length is run through the same Hazen-Williams formula as the straight pipe. PVC uses the Engineering Toolbox thermoplastic table. The source says the table can be used for other thermoplastic pipe of similar design, so PEX uses it too. It is not a PEX-only lab table. Copper uses Copper Tube Handbook Table 14.7 for soldered fittings. A dash in that table is not zero: the form will not count it, and you can type extra equivalent feet instead. Those copper lengths were tabulated at C = 150. If you select 130 or 140, the result says the selected C is applied to the straight pipe and to those fitting feet.
| Fitting | 1/2 inch | 3/4 inch | 1 inch | 1-1/4 inch | 1-1/2 inch | 2 inch |
|---|---|---|---|---|---|---|
| 90° elbow | 1.6 | 2.1 | 2.6 | 3.5 | 4.0 | 5.2 |
| 45° elbow | 0.8 | 1.1 | 1.4 | 1.8 | 2.2 | 2.8 |
| Tee, straight through | 1.0 | 1.4 | 1.7 | 2.3 | 2.7 | 3.5 |
| Tee, side branch | 3.1 | 4.1 | 5.3 | 6.9 | 8.1 | 10.3 |
| Fitting | 1/2 inch | 3/4 inch | 1 inch | 1-1/4 inch | 1-1/2 inch | 2 inch |
|---|---|---|---|---|---|---|
| 90° elbow | 1.0 | 2.0 | 2.5 | 3.0 | 4.0 | 5.5 |
| 45° elbow | 0.5 | 0.5 | 1.0 | 1.0 | 1.5 | 2.0 |
| Tee, straight through | — | — | — | 0.5 | 0.5 | 0.5 |
| Tee, side branch | 2.0 | 3.0 | 4.5 | 5.5 | 7.0 | 9.0 |
No equivalent-length table for galvanized fittings is loaded. Leave those counts at 0 and enter the feet you have from another source in the extra field. This page will not invent them.
Worked example
AWWA C904 Table 4 prints 21 PSI per 100 feet for 3/4 inch PEX at 10 GPM, with C = 150 and the Table 3 average inside diameter of 0.671 inch. This formula gives 21.05 PSI, which is 48.62 feet of head. 48.62 divided by 2.31 rounds to the 21 the table prints. Table 4 shows one decimal under 10 PSI and a whole number at 10 and above. The calculated column below is this formula to two decimals. The printed column is the report.
| Nominal size | GPM | Calculated PSI | Table 4 PSI | Calculated ft/s |
|---|---|---|---|---|
| 1/2 inch | 1 | 1.60 | 1.6 | 1.81 |
| 1/2 inch | 2 | 5.76 | 5.8 | 3.62 |
| 1/2 inch | 3 | 12.20 | 12 | 5.43 |
| 1/2 inch | 5 | 31.40 | 31 | 9.05 |
| 3/4 inch | 2 | 1.07 | 1.1 | 1.81 |
| 3/4 inch | 4 | 3.86 | 3.9 | 3.63 |
| 3/4 inch | 5 | 5.84 | 5.8 | 4.54 |
| 3/4 inch | 10 | 21.05 | 21 | 9.07 |
| 1 inch | 3 | 0.66 | 0.7 | 1.64 |
| 1 inch | 5 | 1.69 | 1.7 | 2.73 |
| 1 inch | 10 | 6.11 | 6.1 | 5.46 |
Two 1 inch PVC 90° elbows are 2 × 2.6 = 5.2 equivalent feet. On 100 feet of straight 1 inch PVC at 10 GPM and C = 150, the total length is 105.2 feet. Loss is 2.51 PSI, 5.80 feet of head. The fitting feet scale the straight-pipe head by 105.2 / 100.
Assumptions and limits
- Hazen-Williams is an empirical water formula. It is not a Darcy-Weisbach calculation, and it does not take a viscosity or a roughness height.
- The run is one material and one nominal size. A reducer or a second pipe is a second calculation.
- Elevation change is not in the result. Add it on the booster calculator if you are sizing a pump. Do not add it twice.
- PVC and galvanized diameters are the largest published Schedule 40 bores. Copper fitting lengths assume C = 150 even when you select 130 or 140.
- Accepted ranges stop at 200 GPM, 2,000 feet of straight pipe, 2,000 extra equivalent feet, and 40 of each fitting. Total length has to be greater than 0.
When to call a pro
- The pipe is a size or a material that is not in these tables, or the fittings are insert fittings whose bore is smaller than the pipe.
- The run includes a meter, a softener, a filter, or a backflow preventer. Those losses are not in this formula.
- You are adding this PSI to a pump curve and the result is a large share of the pressure you have.
Sourced pump specs are in the pump finder. This calculator does not pre-select a use case, because friction loss is a pipe property, not a pump category.
Sources
- AWWA C904 committee report on PEX. Retrieved 2026-11-24. Equation 12 (exponents 1.85 and 4.87, divide feet by 2.31), equation 13 (velocity), Table 3 average inside diameters, Table 4 pressure loss at C = 150. The public PDF is the committee report.
- PPI TR-14, Water Flow Characteristics of Thermoplastic Pipe. Retrieved 2026-11-24. Constant 0.2083 per 100 feet. Exponents 1.852 and 4.8655. C = 150 for thermoplastic pipe.
- Engineering Toolbox, Hazen-Williams coefficients. Retrieved 2026-11-24. PVC and CPVC 150. Galvanized iron 120. Copper 130–140.
- Engineering Toolbox, PVC and CPVC pipe dimensions. Retrieved 2026-11-24. ASTM D1785 Schedule 40 outside diameter and minimum wall. Inside diameter used here is outside diameter minus twice that wall.
- Engineering Toolbox, steel pipe dimensions. Retrieved 2026-11-24. ASME B36.10 Schedule 40 inside diameter, used for galvanized. No zinc allowance is in the table.
- Engineering Toolbox, PVC fitting equivalent length. Retrieved 2026-11-24. Used for PVC and, as the page allows, other thermoplastic pipe.
- Copper Tube Handbook Table 14.2b, Type L inside diameter. Retrieved 2026-11-24.
- Copper Tube Handbook Table 14.7, fitting equivalent length. Retrieved 2026-11-24. Soldered fittings. Lengths based on C = 150. Dashes are not stored as zero.
- Engineering Toolbox, pump head and pressure. Retrieved 2026-11-24. 2.31 feet of water per PSI. The same constant is in the well and booster calculator.