Well pump and booster pump size calculator

Updated . Editor: Evan Heath. About the editor

This calculator estimates the flow and pressure a residential booster or well pump has to deliver. Peak flow comes from Hunter's curve, IPC Appendix E Table E103.3(3), using fixture-unit loads in Table E103.3(2). Boost equals target pressure minus incoming pressure, plus 0.433 PSI per foot of lift. You get a GPM step and a head band to compare with a pump curve.

The arithmetic runs in your browser. The entries are not sent to a server to be calculated. Pipe friction is not included. The friction loss calculator estimates that loss for a pipe run. This page does not add it for you. The band is a flow step and a head range, and the page does not name a pump. If you have not confirmed whether your issue is true low pressure or a plumbing restriction, start with the low water pressure diagnosis guide.

Your house

01 · Toilet supply
A flush tank is the storage tank on a typical house toilet. Choosing it uses the flush-tank column of the IPC Appendix E fixture-unit and demand tables.
A flushometer is a tankless toilet valve. On the IPC Appendix E tables this page uses, a bathroom group is 8.0 fixture units and a toilet is 6.0, instead of 3.6 and 2.2 for a flush tank.

Flush tank: a bathroom group is 3.6 fixture units and a toilet is 2.2. Flushometer: a bathroom group is 8.0 and a toilet is 6.0. The other rows stay the same: lavatory 0.7, and shower, bathtub, kitchen sink, dishwasher, clothes washer, and laundry tray are 1.4 each.

02 · Fixture counts

Use bathroom groups or the separate rows, not both for the same room. A half bath is a toilet and a lavatory on their own rows. Zero counts as none.

A bathroom group is one full bathroom counted as a single unit: a toilet, a lavatory, and a tub or shower together, from the IPC Appendix E private fixture-unit table this calculator uses. Do not also count those same fixtures on the separate toilet, lavatory, shower, or bathtub rows.
A toilet that is not already inside a bathroom group. A half bath belongs here as a toilet and a lavatory on their own rows, and a flush-tank toilet is 2.2 fixture units on the IPC private table.
A bathroom sink that is not already inside a counted bathroom group. The IPC Appendix E private-fixture table counts a lavatory as 0.7 fixture units.
A shower that is not already inside a counted bathroom group. The IPC Appendix E private-fixture table counts a shower as 1.4 fixture units.
A bathtub that is not already inside a counted bathroom group. The IPC Appendix E private-fixture table counts a bathtub as 1.4 fixture units.
A kitchen sink counted on its own row. The IPC Appendix E private-fixture table counts one as 1.4 fixture units.
A dishwasher counted on its own row. The IPC Appendix E private-fixture table counts one as 1.4 fixture units.
An 8 lb clothes washer, the size named on the IPC Appendix E private-fixture table this calculator uses. That table counts it as 1.4 fixture units.
A laundry tray counted on its own row. The IPC Appendix E private-fixture table counts one as 1.4 fixture units.
Gallons per minute of constant uses such as hose bibbs and irrigation, added after the fixture-unit curve rather than as fixture units. The IPC appendix example uses 5 GPM for each hose bibb; use 0 when you are sizing the house fixtures only.

Hose bibbs and irrigation are not fixture units. Add their gallons per minute here. The IPC example uses 5 GPM for each hose bibb. Use 0 when you are sizing the house fixtures only.

03 · Lift & pressure
How many floors the water is raised above the pump. One floor is counted as 10 feet, and that 10 feet is a planning allowance, not a code value.

How many floors the water is raised above the pump. One floor is counted as 10 feet. That 10 feet is a planning allowance, not a code value.

Measured height from the pump to the highest outlet. A number here replaces the floor count and is not added on top of it; leave it blank to use the floors times 10 feet.

Leave blank to use the floor count times 10 feet. Enter a measured height from the pump to the highest outlet when you have one. A number here is used instead of the floor count, not in addition to it.

Feet from the water surface up to the point where you read incoming pressure. Leave 0 for a city-water booster, or when the gauge reading already includes this lift, and do not enter the drilled depth of the well.

Optional. Feet from the water surface up to the point where you read incoming pressure. Leave 0 for a city-water booster, or when the gauge reading already includes this lift. Do not enter the drilled depth of the well.

For city water, the gauge reading at the pump inlet. For a submersible pump that starts from the water level, enter 0 and put that water level in the field above.

For city water, read the gauge at the pump inlet. For a submersible pump that starts from the water level, enter 0 and put that water level in the field above.

The pressure you want at the highest outlet. Enter the number you want.

The pressure you want at the highest outlet. Enter the number you want.

How the numbers are calculated

Fixture units come from the total column of IPC Table E103.3(2) for private fixtures:

  • Bathroom group, flush tank: 3.6. The same group with a flushometer valve: 8.0.
  • Toilet, flush tank: 2.2. Toilet, flushometer valve: 6.0.
  • Lavatory: 0.7. Shower, bathtub, kitchen sink, dishwasher, 8 lb clothes washer, and laundry tray: 1.4 each.

A bathroom group already includes one toilet, one lavatory, and one tub or shower. Adding those rows on top of a group counts the room twice. Peak gallons per minute are then read from Table E103.3(3). A value that lands on a printed row is used as printed. A value between two rows is a straight line between those two published gallons-per-minute figures. A flush-tank total below 1 fixture unit uses the first row, 3.0 GPM. Hose bibbs, irrigation, and other constant uses are added afterward in GPM. The appendix's own example is 120 fixture units = 48 GPM, then two hose bibbs at 5 GPM each, for 58 GPM.

Boost PSI = (target PSI − incoming PSI) + (lift feet × 0.433)
Head feet = boost PSI × 2.31
Lift feet = vertical lift + static or pumping water level

2.31 feet of water per PSI, and 0.433 PSI per foot, are the two factors used here. Multiplying them does not land on exactly 1 (2.31 × 0.433 = 0.99963), so a round trip between PSI and feet is off by a few hundredths of a percent. IPC Appendix E's sample problem prints 21 feet × 0.43 = 9.03 PSI. That is the same per-foot factor rounded to two decimals. This page keeps 0.433, so 21 feet is 9.093 PSI.

The flow steps are 5, 7, 10, 12, 15, 20, 25, 30, 35, and 40 GPM. Those are the pump discharge rates listed on Amtrol's Well-X-Trol quick-sizing card. Here they are only steps. The result is the smallest step at or above the peak, and the 50-foot head band that contains the required head. The card's tank model picks are not used.

Worked example

Two bathroom groups are 2 × 3.6 = 7.2 fixture units. A kitchen sink, a dishwasher, and a clothes washer add 3 × 1.4 = 4.2. The total is 11.4. Table E103.3(3) lists 11 fixture units as 15.4 GPM and 12 fixture units as 16.0 GPM. The point 0.4 of the way from 11 to 12 is 15.4 + 0.4 × (16.0 − 15.4) = 15.64 GPM.

One floor at the 10-foot allowance is 10 feet of lift, which is 10 × 0.433 = 4.33 PSI. A 55 PSI target minus 40 PSI incoming, plus 4.33, is 19.33 PSI. Head is 19.33 × 2.31 = 44.65 feet. 15.64 GPM rounds up to the 20 GPM step, and 44.65 feet sits in the 0–50 foot band.

The same entries produce 15.64 GPM, 19.33 PSI, and 44.65 feet of head.

Assumptions and limits

  • The demand table is a probability curve for intermittent fixtures. It is not the sum of every fixture running at once, and it is not a promise of what a well can yield.
  • Appendix E is a pipe-sizing method, and it is not mandatory unless the local code adopts it. This page uses the fixture loads and the demand table only. It does not subtract meter loss, filter loss, softener loss, or pipe friction. Pipe friction is a separate estimate on the friction loss calculator. This page does not look up the residual pressure in IPC Table 604.3.
  • The 10 feet per floor figure is a planning allowance. A measured lift replaces it.
  • Water level means the static level, or the pumping level if you have it. Well depth is a different number and will overstate the lift if you enter it here.
  • Entering incoming pressure and a water level together counts both. Leave the water level at 0 when the gauge reading already includes that lift.
  • The head band edges are 50-foot reading marks for a pump curve. They are not a manufacturer's class list.
  • Accepted ranges stop at 500 of any one fixture, 5,000 fixture units, 200 GPM of continuous flow, 150 PSI, 40 floors, and 2,000 feet of combined lift.

When to call a pro

  • You do not know how many gallons per minute the well will give up. A pump cannot deliver more than the well yields.
  • The pump is a shallow-well jet that has to lift water by suction. Suction lift has a hard limit, and this page does not calculate it.
  • The run of pipe is long, the pipe is small, or there is a meter, softener, filter, or backflow preventer in the path.
  • Incoming pressure is already around 80 PSI or higher. Adding a booster on top of that can be the wrong move.
  • The result is above the 40 GPM step, or the head is hundreds of feet.
  • This is a new well, a shared well, or a building that is not a house.

Tank volume is a separate step. Once you have a pump flow, the pressure tank size calculator turns that flow and the switch setting into drawdown and a minimum tank volume. The pump finder opens with the whole-house use case selected.

Sources