Methodology

Updated . Editor: Evan Heath. About the editor

The editor is Evan Heath. This page describes the dataset and the calculators as they are today. Booster Pump Reviews does not operate a laboratory and does not claim hands-on testing.

Specifications

The pump finder lists the 16 records in the dataset: 14 pumps and 2 pressure tanks. Those records hold 203 specifications. Every specification is stored as a value, an optional unit, a source URL, and a retrieval date. A record that omits the source URL or the retrieval date fails the build.

All 203 specifications were retrieved on 2026-11-24. They cite 22 distinct source URLs. The source catalog for that retrieval says its scope is a manufacturer spec sheet, manual, or manufacturer product page only, and that it does not use prices, ratings, Amazon listings, or estimates.

Two records do not use a manufacturer host. Polaris PB4-60 cites H0399500_REVF.pdf on millerpools.com. Polaris PB4SQ cites the installation and operation manual on lesl.a.bigcontent.io. The spot check dated 2026-11-24 says the manufacturer URLs for those models returned 404, and that those copies were the ones read.

The finder does not rank models and does not show prices.

Owner reports

A separate file exists for each of the same 16 models. It is not shown as a rating on the site. There is no AggregateRating and no review score computed by this site.

Each file lists the public posts that were read (sources_read). sample_size is the number of those posts. retrieved_on on every file, and on every post in them, is 2026-11-24. Across the 16 files, 107 posts were read: 63 recorded as page_fetch and 44 recorded as search_index_extract.

The sites on those 107 posts are Amazon (41), Reddit (28), ProductReview.com.au (14), VEVOR (9), SupplyHouse (6), iRV2 (4), Terry Love Plumbing (3), Amazon.de (1), and InspectApedia (1).

A file is marked thin_data when fewer than 5 posts were read, and its note says fewer than 5 sources. Seven files are thin:

  • Amtrol Well-X-Trol WX-202: 3
  • Amtrol Well-X-Trol WX-250: 3
  • Davey BT14-30: 0
  • Franklin VersaBoost Pro FE-VBPRO-115: 0
  • Polaris PB4SQ: 0
  • Seaflo SFDP1-040-060-55: 0
  • Shurflo 4008-101-E65: 2

The other nine files have 5 or more posts. The largest are Grundfos SCALA2 3-45 (25) and Grundfos SCALA1 3-45 (21). A file with no posts stays empty. Manufacturer datasheets are not counted as owner reports.

A quote, when one is stored, is at most 25 words, at most 3 quotes per model, and it has to match a post that was read. The 16 files hold 27 quotes. A star average is stored only when a page displayed that number. It is copied, not calculated here. The files hold five of those copied averages. The site does not publish them as its own rating.

Each file names snapshot_dir as research/sentiment-snapshots/<model_id>. Those snapshot paths are part of the data record. They are not pages on this site.

Calculators

Four calculators run in the browser. The entries are not sent to a server to be calculated. Each page below states the formula, the limits, and the documents it cites. Those documents were retrieved on 2026-11-24.

  • Well pump and booster pump size. Fixture units come from IPC 2024 Appendix E, Tables E103.3(2) and E103.3(3), as published in the Vermont adoption on UpCodes. Peak gallons per minute are read from Table E103.3(3), with a straight line between printed rows. Boost PSI = (target PSI − incoming PSI) + (lift feet × 0.433). Head feet = boost PSI × 2.31. The 0.433 and 2.31 factors are the Engineering Toolbox hydrostatic-pressure and pump-head pages. The flow steps 5, 7, 10, 12, 15, 20, 25, 30, 35, and 40 GPM are the pump discharge rates on Amtrol’s Well-X-Trol card MC7025 (03/26). The card’s tank model picks are not used. Pipe friction is not included.
  • Pressure tank size. Drawdown gallons = pump GPM × run time in minutes. The acceptance factor is Boyle’s law for a precharged tank, using gauge PSI plus 14.7. Minimum tank gallons = drawdown / that factor. The 14.7 figure is the Engineering Toolbox sea-level atmosphere, rounded from 14.696. Drawdown cells are checked against Amtrol card MC7025 (03/26). The one-minute minimum run is the Franklin Electric AIM manual line on dissipating start heat. One minute per horsepower, when horsepower is entered, is a planning allowance on this page, not a figure printed in that manual.
  • RO booster pump check. Osmotic PSI = TDS mg/L ÷ 100. Net driving PSI = inlet PSI − osmotic PSI − empty-tank precharge PSI. Estimated gallons per day scale the rated gallons per day by the net-pressure ratio and by the FilmTec temperature-correction equations (3020 and 2640). The page compares net pressure with three published marks: about 30 PSI (WaterWorld), 40 PSI (the bottom of the 40–100 PSI operating range in the 1 May 2024 WC&P article), and 50 PSI (that article’s remark about a 30/50 well switch). Sources on the page are WQA Article 4, that WC&P article, WaterWorld, the DuPont FilmTec reverse osmosis and nanofiltration technical manual, Mar Cor Tech Note 113, the FilmTec TW30-1812 data sheet, and WQA’s Getting Smart With Reverse Osmosis Systems. The page does not name a pump.
  • Pipe friction loss. Head feet = 0.2083 × (L / 100) × (100 / C)^1.85 × Q^1.85 / d^4.87. PSI = head feet / 2.31. Velocity = 0.4085 × Q / d^2. C is 150 for PVC and for PEX, 120 for galvanized, and 130 or 140 for copper. The 1.85 and 4.87 exponents and the divide-by-2.31 step are equation 12 of the AWWA C904 committee report. The 0.2083 constant is PPI TR-14. C values for PVC, galvanized, and copper are the Engineering Toolbox Hazen-Williams coefficients. PEX uses C = 150 from the AWWA report. Inside diameters and fitting lengths are the tables named on that page. The result is not a pump recommendation.

Corrections

Send a correction to contact@revspace.net. The date under the title is the date that page was last updated. A specification change still has to keep a source URL and a retrieval date, or the build fails.