Does my RO system need a booster pump?
Net driving pressure is inlet PSI minus 1 PSI per 100 mg/L of TDS, minus the empty-tank precharge. Estimated production is the rated gallons per day times that net pressure over the rating pressure, times a temperature factor from the FilmTec equations. This page then places the net pressure against three published marks: about 30 PSI, 40 PSI, and 50 PSI. It does not name a pump.
The arithmetic runs in your browser. The entries are not sent to a server to be calculated. A result under 40 PSI is a pressure problem. Whether the useful device is an electric booster or a permeate pump depends on what is low, and that difference is explained below.
How the numbers are calculated
Osmotic pressure is TDS in mg/L divided by 100. WQA Article 4 and the 1 May 2024 WC&P article both use 1 PSI per 100 ppm. Empty-tank net driving pressure subtracts that osmotic pressure and the empty-tank air charge:
Osmotic PSI = TDS mg/L ÷ 100
Net driving PSI = inlet PSI − osmotic PSI − empty-tank precharge PSI
WaterWorld's worked line is 45 PSI − 8 PSI (800 ppm) − 6 PSI empty tank = 31 PSI. WC&P's line is 40 PSI and 500 ppm = 35 PSI of net driving force. That sentence does not subtract a precharge, so this page reproduces it with precharge at 0. The same article says a full tank can sit near 35 or 40 PSI and that the empty-tank subtraction does not describe the tank while it is filling. This check is the empty-tank case only.
Production scales with net driving pressure and with the FilmTec permeability temperature factor. Cold water is below 1. At 25 °C and above, the constant in the exponent changes. T is degrees Celsius. 77 °F is exactly 25 °C because °C = (°F − 32) × 5/9.
TCF = exp(3020 × (1/298 − 1/(273 + T))) when T is 25 °C or below
TCF = exp(2640 × (1/298 − 1/(273 + T))) when T is 25 °C or above
Gallons per day = rated gallons per day × (net driving PSI ÷ rating net PSI) × (TCF at the water ÷ TCF at the rating)
The FilmTec manual rounds this factor to 0.70 at 15 °C and 0.58 at 10 °C. Mar Cor Tech Note 113 prints the same factor to three decimals (15 °C = 0.703, 10 °C = 0.584, 25 °C = 1.000) and says the two constants also came from correspondence with Applied Membranes. FilmTec Table 50 is the reciprocal of this factor (10 °C = 1.711). A measured flow is divided by Table 50 to correct it back to 25 °C. This page multiplies by the equations above. It does not multiply by Table 50.
If you leave incoming TDS blank, osmotic pressure is not subtracted. If you leave test-solution TDS blank, the rating side is the applied test pressure only. This page does not invent a test TDS such as 500 ppm. Test permeate pressure is not in the published rating line, so it is not subtracted. If net driving pressure is not above zero, estimated production is zero. If the test-solution osmotic pressure is not below the applied test pressure, the form stops.
The 30, 40, and 50 PSI marks
These are three different sentences, not one lab limit of 40–50 PSI.
- About 30 PSI of net pressure is WaterWorld's note for satisfactory results. Net pressure under 30 PSI is under that note and under 40.
- 40 PSI is the bottom of the operating range WC&P says manufacturers typically print as 40–100 PSI. The same article says a system at 40 PSI will not work as expected when the membrane is rated at 60 PSI, and it calls the 35 PSI net-driving-force example an unacceptable rejection drop.
- 50 PSI is WC&P's remark that a 30/50 well switch never sees 50 PSI and is always seeing less than optimal pressure. That sentence is about inlet pressure on that switch. It is not a net-driving-pressure spec from a membrane manual. This page still reports net pressure under 50 PSI as its own band, and it says so in the result.
A result under 40 PSI means the empty-tank net pressure is below the stated operating-range floor. It does not name a product, and it does not say an electric booster is the only device that matters. TDS over 500 mg/L gets a separate note, from WC&P's rule of thumb for considering a booster, especially on a 30/50 well. This page does not know your pressure switch.
Permeate pump and electric booster
WQA's definition of a booster pump is an auxiliary pump that boosts incoming line pressure to the membrane. Its definition of a permeate pump is a device that uses the pressure of the waste or feed line to add pressure to the permeate going to the tank. That extra push reduces the effect of storage-tank backpressure on permeate flow and on water efficiency. The permeate pump is not an electric feed-pressure pump.
WC&P separates the two jobs. A booster raises net driving force when inlet pressure is low or TDS is high. It does not stop TDS creep: as the storage tank fills, tank pressure still pushes back on the membrane, and the last water into the tank is made at a lower net pressure. A permeate pump keeps the membrane at about the empty-tank reduction (the article uses about 5 PSI) no matter how full the tank is. It does not raise a low incoming line pressure.
The same article says an automatic shutoff closes when tank pressure reaches roughly two-thirds of feed pressure. At 80 PSI of feed, that is about 52 PSI in the tank. A shutoff switch set at 60 PSI would never turn an electric booster off. This page does not size that switch. It is the reason a higher feed pressure is not automatically a better setup.
WQA says the empty air charge in a pressurized RO tank is approximately 5 PSI, and its performance article says the typical empty charge is 5–10 PSI. A precharge above 10 PSI is flagged. Read it with the tank empty. This is the small RO storage tank, not the well pressure tank on the pressure tank size calculator.
Worked example
WaterWorld: 45 PSI inlet, 800 mg/L, 6 PSI empty tank. Osmotic pressure is 800 ÷ 100 = 8 PSI. Net driving pressure is 45 − 8 − 6 = 31 PSI. That is under 40 and at least about 30, so the band is under 40.
Scale a 50 gallon-per-day rating tested at 50 PSI and 77 °F, with test TDS left blank. The pressure ratio is 31 ÷ 50. The temperature ratio at 77 °F is 1. Estimated production is 50 × 31/50 × 1 = 31 gallons per day. The same entries on this page are 31 PSI and 31.0 gallons per day.
At 59 °F the water is 15 °C. The temperature factor is 0.703, which is the FilmTec equation at 15 °C (the manual rounds it to 0.70, and Mar Cor prints 0.703). Production is 31 × that factor = 21.8 gallons per day. Net pressure stays 31 PSI. Temperature does not change the pressure band.
WC&P: 40 PSI and 500 mg/L, precharge 0, is 35 PSI of net driving force. Against a 50 gallon-per-day rating at 60 PSI and 77 °F, with test TDS blank, estimated production is 29.2 gallons per day. The article's rejection chart is not reproduced here. The 35 PSI figure is the pressure arithmetic only.
Assumptions and limits
- The result is empty-tank net pressure and a production estimate. It is not a rejection percentage, a recovery percentage, or a water-quality test.
- The temperature factor is for thin-film membranes using the FilmTec constants. It is not a cellulose-acetate table.
- Printed temperature tables checked here run about 36–95 °F (2–35 °C). Outside that span the equation is still applied, and the result says so.
- Inlet pressure above 100 PSI is above the top of the 40–100 PSI range in the WC&P article. This page does not know the housing rating.
- 65 PSI can be typed as a test pressure. No retrieved table defines 65 PSI as a standard rating pressure.
- Accepted ranges stop at 150 PSI inlet, 2,000 gallons per day, 33–113 °F, 80 PSI precharge, and 10,000 mg/L TDS.
When to call a pro
- The water has hardness, iron, manganese, or hydrogen sulfide that the membrane's pretreatment does not already handle. WC&P says those have to be treated before the RO inlet.
- You need a contaminant reduction, such as nitrate, and the net pressure is in the range the WC&P article calls less than optimal.
- An electric booster is already installed and its shutoff switch may sit above about two-thirds of the feed pressure.
- You do not know whether the gauge reading is the empty-tank air charge or the pressure of a tank that still holds water.
Sourced RO booster specs are in the pump finder, with the RO use case selected.
Sources
- WQA Knowledge Base, Article 4, POU Reverse Osmosis Performance and Sizing. Retrieved 2026-11-24. Net driving pressure subtracts osmotic pressure and tank backpressure. 1 PSI per 100 mg/L. Typical empty-tank charge 5–10 PSI.
- WC&P Online, 1 May 2024, How to Enhance Reverse Osmosis Performance. Retrieved 2026-11-24. Operating range 40–100 PSI. 40 PSI and 500 ppm = 35 PSI net driving force. 30/50 well switch and the 50 PSI remark. Booster versus permeate pump. Automatic shutoff at roughly two-thirds of feed pressure. TDS over 500 as a rule of thumb.
- WaterWorld, Avoiding Residential RO Pitfalls. Retrieved 2026-11-24. 45 − 8 − 6 = 31 PSI, and about 30 PSI of net pressure.
- DuPont FilmTec reverse osmosis and nanofiltration technical manual, version 20 (August 2026). Retrieved 2026-11-24. Equations 73 and 74. Table 50 is the reciprocal and is not the factor this page multiplies by.
- Mar Cor Tech Note 113, Temperature Correction Factors for Thin Film Membranes. Retrieved 2026-11-24. Three-decimal permeability table. The note records the same constants from correspondence with Applied Membranes.
- FilmTec home drinking-water RO elements product data sheet (TW30-1812 series). Retrieved 2026-11-24. Applied test pressure 50 PSI, 250 ppm, 77 °F, 15 percent recovery. The sheet contrasts elements rated at 60 PSI.
- WQA, Getting Smart With Reverse Osmosis Systems, Appendix A. Retrieved 2026-11-24. Definitions of a booster pump and a permeate pump. Empty air charge approximately 5 PSI.