Pump finder

Updated . Editor: Evan Heath. About the editor

This page lists every pump and pressure tank in the sourced dataset. Filters cover use case, supply voltage, flow, pressure, and speed control. Each figure is a published spec, or the card says not published. A missing field does not remove a record. The page does not rank models or show prices.

Size a house with the whole-house booster sizing calculator, or size a tank with the pressure tank size calculator. Check an RO booster with the RO booster pump check, or estimate pipe loss with the pipe friction-loss calculator. A calculator can open this page with filters filled in, for example whole-house, 115 V, at least 10 GPM, and at least 40 PSI. The parameters are use, voltage, flowMin, flowMax, pressureMin, pressureMax, and speed. Repeat a parameter or separate values with commas. use accepts whole-house, ro, rv-12v, pool-cleaner, and pressure-tank. voltage accepts 12, 24, 115, and 230 (220–240 V). speed accepts constant-pressure or fixed-speed.

Filters

Filters

A record is removed only when a published value disagrees with the filter. If that field is not published, the record stays in the list.

01 · Use caseUse case is derived. It is not a column in the dataset: a published application spec is read first, and if that field does not name a use, other published fields decide.
A published application that says whole-house is used first. Otherwise the record is whole-house when it is not an RO, 12 V, pool-cleaner, or pressure-tank match, it has no pressure-switch spec, and it publishes at least 8 GPM or at least 80 ft of head.RO means a published application says RO boost or reverse osmosis. If that field does not name a use, a published compatible RO systems spec also counts.RV / 12V means the only published supply voltage is 12 V, when the application spec does not already name a use.Pool cleaner means a published application names a pressure-side pool cleaner or a pressure cleaner booster. If that field does not name a use, a Polaris record that is not a pressure tank also counts.Pressure tank means the product type on the record is a pressure tank. It is not inferred from the pressure spec on a pump.
02 · Supply voltageSupply voltage is the published voltage or supply-voltage spec, read as 12 V, 24 V, 115 V, or 220–240 V. A dual-voltage spec matches each voltage it names.
03 · Speed controlConstant pressure means a pressure setting range is published, or the spec text says constant pressure, variable speed, or VFD. Fixed speed means a pressure switch, one RPM, or text that says fixed speed; otherwise speed is not published.
Kept when a pressure setting range is published, or the spec text says constant pressure, variable speed, or VFD.
Kept when a pressure switch is published, one RPM is published, or the spec text says fixed speed.
04 · Flow (GPM)Flow is the first published of max flow, nominal flow, open flow, or flow rate, compared in gallons per minute. Other published units are converted, and a missing flow does not remove the record.
05 · Pressure (PSI)Pressure is the first published pressure or head spec, compared in PSI. A published range matches when it overlaps the filter, feet of head are divided by 2.31, and a missing pressure does not remove the record.

16 records.

Whole-house

Aquastrong · Pump

Constant pressure

Aquastrong Smart 45

Product type
Pump
Use case (derived)
Whole-house [4]
Supply voltage
115 V [4]
Flow
Max Flow: 1500 GPH [4]
Pressure
Pressure Setting Range: 1.5 to 5.5 bar (22 to 80 psi) [4]
Speed control (derived)
Constant pressure [4]
Frequency
60 Hz [4]
Rated Power
3/4 HP [4]
Max Current
6.8 A [4]
Max Head
150 ft [4]
Max Speed
5200 r/min [4]
Max Suction Head
26 ft [4]
Inlet Connection
1 in NPT [4]
Outlet Connection
1 in NPT [4]
Max Ambient Temperature
39 to 130 °F [4]
Liquid Temperature Range
32 to 175 °F [4]
Ingress Protection
IPX5 [4]
Factory Pressure Setting
3 bar (44 psi) [4]
Pressure Tank Precharge
1.25 bar (18 psi) [4]
Max Inlet To Outlet Pressure Difference
3.5 bar (51 psi) [4]
Warranty
24 months [4]
Noise Level
55 dB(A) in typical use [5]

DAB · Pump

DAB Esybox Mini 3

Product type
Pump
Use case (derived)
Whole-house [7]
Supply voltage
1x220-240 V [7]
Flow
Flow Rate: 4.8 m3/h [7]
Pressure
Head: 55 m [7]
Speed control (derived)
not published
Head At Flow 4 8 M3 H
4 m [7]
Liquid Temperature Range
+5°C to +40°C [7]
Max Ambient Temperature
50 °C [7]
Max Suction Depth
8 m [7]
Max Working Pressure
7.5 bar (750 kPa) [7]
Supply Frequency
50/60 Hz [7]
Input Power P1 Max
0.85 kW [7]
Horsepower
1.1 HP [7]
Current
4.8 A [7]
Inlet Connection
1 in [7]
Outlet Connection
1 in [7]
Dimensions
A 439 mm, B 263 mm, C 46 mm, D 143 mm, E 60.7 mm, F 106.7 mm, G 279.5 mm, H 236 mm, I 40.5 mm, L 152 mm, M 46 mm, N 101.7 mm, P 140 mm, Q 140 mm, R 155.5 mm, S 47.8 mm, T 133 mm, V 54.5 mm [7]
Weight
14.6 kg [7]

Davey · Pump

Davey BT14-30

Product type
Pump
Use case (derived)
Whole-house [8]
Supply voltage
not published
Flow
Nominal Flow: 14 gpm [8]
Pressure
Nominal Pressure: 30 psi [8]
Speed control (derived)
not published
Maximum Inlet Pressure
60 psi [8]
Maximum Boost
40 psi [8]
Max Liquid Temperature
158 °F [8]
Max System Pressure
100 psi [8]
Max Pump Casing Pressure
116 psi [8]
Supply Frequency
60 Hz [8]
Input Power P1
0.92 kW [8]
Output Power P2
0.73 kW [8]
Full Load Current
7.8 A [8]
Inlet Connection
1-1/4 in F [8]
Outlet Connection
1 in M [8]
Dimensions
A 13.80 in, B 4.33 in, C 12.20 in, D 4.33 in, E 2.40 in, F 5.70 in [8]
Net Weight
26.5 lb [8]
Warranty
36 months [9]

Franklin Electric · Pump

Constant pressure

Franklin VersaBoost Pro FE-VBPRO-115 (93381101)

Product type
Pump
Use case (derived)
Whole-house [10]
Supply voltage
115 VAC [10]
Flow
Max Flow: 18 gpm / 1080 gph / 25920 gpd / 4088 Lph / 68.14 Lpm / 4.09 m3/h [10]
Pressure
Pressure Setting Range: 14 to 80 psi [11]
Speed control (derived)
Constant pressure [11]
Horsepower
0.8 hp [10]
Frequency
60 Hz [10]
Shutoff Head
185 ft / 56.39 m [10]
Minimum Head
32 ft / 9.75 m [10]
Min Fluid Temperature
33° F (0.56° C) [10]
Max Fluid Temperature
104° F (40° C) [10]
Max Operating Temperature
122° F (50° C) [10]
Inlet Connection
1 in FNPT [10]
Outlet Connection
1 in FNPT [10]
Dimensions
length 10.84 in (27.53 cm), width 13.3 in (33.78 cm), height 18 in (45.72 cm) [10]
Weight
39 lb (17.69 kg) [10]
Tank Capacity
0.53 gal (2 L) [10]
Warranty
36 months [10]
Noise Level
as low as 45 dB [11]
Max System Pressure
100 psi (6.9 bar) [11]

Grundfos · Pump

Grundfos SCALA1 3-45 (99631742)

Product type
Pump
Use case (derived)
Whole-house [12]
Supply voltage
115 V [12]
Flow
Nominal Flow: 15.8 US gpm (3.6 m3/h) [12]
Pressure
Max Head: 150 ft (45 m) [12]
Speed control (derived)
not published
Frequency
60 Hz [12]
Power Plug
NEMA 5-15 [12]
Max Ambient Temperature
131° F (55° C) [12]
Max Liquid Temperature
113° F (45° C) [12]
Max System Pressure
115 psi (8 bar) [12]
Max Inlet Pressure
43 psi (3 bar) [12]
Nominal Head
82 ft (25 m) [12]
Noise Level
<55 dB(A) [12]
Net Weight
26.5 lbs (12.0 kg) [12]
Max Suction
26 ft (8 m) [12]

Grundfos · Pump

Grundfos SCALA2 3-45 (93013251)

Product type
Pump
Use case (derived)
Whole-house [13]
Supply voltage
115 V [14]
Flow
not published
Pressure
Max Head: 147 ft (45 m) [13]
Speed control (derived)
not published
Max System Pressure
145 psi (10 bar) [13]
Max Inlet Pressure
87 psi (6 bar) [13]
Max Liquid Temperature
113° F (45° C) [13]
Max Ambient Temperature
113° F (45° C) [13]
Net Weight
21.3 lbs (9.66 kg) [13]
Frequency
60 Hz [14]
Max Current
4.9 A [14]
Input Power P1
550 W [14]
Standby Power
2 W [14]
Power Plug
IEC type B, NEMA 5-15P [14]
Pipe Connections
R 1 in or NPT 1 in [14]
Inlet Connection
NPT 1 in (inch row) or R 1 (metric row) [14]
Outlet Connection
NPT 1 in (inch row) or R 1 (metric row) [14]
Dimensions
H1 11.9 in (302 mm), H2 9.2 in (234 mm), H3 4.5 in (114 mm), L1 15.9 in (403 mm), W1 7.6 in (193 mm) [14]
Noise Level
< 44 dB(A) [14]
Noise Measurement
44 dB(A) measured at duty point Q = 1 m3/h and H = 19 m in accordance with ISO 3745 [14]

RO

Aquatec · Pump

Aquatec 8800 Series 88X2, 24 VAC (88XX-2X03-B424)

Product type
Pump
Use case (derived)
RO [6]
Supply voltage
24 VAC [6]
Flow
Open Flow: 2.6 LPM [6]
Pressure
not published
Speed control (derived)
not published
Application
Pre-Filter Water Treatment (R.O. Boost) [6]
Current At Open Flow
0.7 A [6]
Flow At 80 Psi
1.4 LPM [6]
Current At 80 Psi
1.65 A [6]
Max Inlet Pressure
60 PSI [6]
Max Liquid Temperature
170°F (77°C) [6]
Weight
6 lb [6]
Ports
open ports for 3/8 in compression fitting [6]
Prime
6 ft [6]
Max Motor Surface Temperature
150°F (66°C) [6]
Performance Figures
ALL PERFORMANCE AND HEAT RISE FIGURES ARE APPROXIMATE. ACTUAL VALUES WILL VARY WITH AMBIENT CONDITIONS. [6]

RV / 12V

Remco · Pump

Remco 55AQUAJET-ARV

Product type
Pump
Use case (derived)
RV / 12V [18]
Supply voltage
12 VDC [18]
Flow
Max Flow: 5.3 GPM (20.06 LPM) [18]
Pressure
Shutoff Pressure: 65 PSI (4.5 bar) [18]
Speed control (derived)
not published
Ports
3/4 in quick attach female [18]
Max Liquid Temperature
140°F (60°C) [18]
Voltage Range
11.5 VDC to 14.5 VDC [18]
Max Current
10 A [18]
Dry Prime
14 feet (4.2 m) [18]
Net Weight
8.0 lbs (3.62 kg) [18]
Dimension Callouts
4.60 in (116.83 mm); 4.84 in (122.93 mm); 8.89 in (225.80 mm) [19]

Shurflo · Pump

Shurflo Revolution 4008-101-E65

Product type
Pump
Use case (derived)
RV / 12V [21]
Supply voltage
12 V DC [21]
Flow
Open Flow: 3.0 GPM (11.3 LPM) at 0 PSI [21]
Pressure
Shutoff Pressure: 55 PSI (3.8 bar) ± 2 PSI [21]
Speed control (derived)
not published
Current At 0 Psi
2.2 A [21]
Restart Pressure
40 PSI (2.8 bar) ± 2 PSI [21]
Max Bypass Pressure
62 PSI (4.2 bar) ± 2 PSI [21]
Ports
1/2 in-14 NPSM-Male [21]
Max Liquid Temperature
130°F (54°C) [21]
Max Inlet Pressure
30 PSI (2.06 bar) [21]
Recommended Fuse
10 A [21]
Net Weight
5 lbs (2.3 kg) [21]

Pool cleaner

Polaris · Pump

Fixed speed

Polaris PB4-60

Product type
Pump
Use case (derived)
Pool cleaner [16]
Supply voltage
230/115 V, 60 Hz, 1 PH [16]
Flow
not published
Pressure
Minimum Outlet Pressure: 45 psi [16]
Speed control (derived)
Fixed speed [16]
Application
Pressure Cleaner Booster Pump. The Polaris booster pump, PB4-60, supplies high pressure water to the Polaris pool cleaner to optimize cleaner efficiency. [16]
Total Horsepower
1.13 THP [16]
Wef
0.5 [16]
Rpm
3450 RPM [16]
Service Factor Amps
6.4/12.8 A [16]
Factory Wiring
230 V, and can be wired for 115 V or 230 V [16]
Inlet Pipe Minimum
3/4 in [16]
Dedicated Return Pipe
minimum diameter 3/4 in; 1-1/2 in is recommended [16]

Polaris · Pump

Fixed speed

Polaris PB4SQ

Product type
Pump
Use case (derived)
Pool cleaner [17]
Supply voltage
230/115 VAC, 1 phase, 60 Hz [17]
Flow
not published
Pressure
not published
Speed control (derived)
Fixed speed [17]
Application
Pressure Cleaner Booster Pump. Using this pump for any purpose other than running a pressure side pool cleaner will void the warranty. [17]
Motor Power
725 W [17]
Horsepower
0.97 HP [17]
Service Factor
1 [17]
Rpm
3450 RPM [17]
Amps
4.5/9.2 A [17]
Factory Wiring
factory wired for 230 VAC; can be wired for 115 VAC [17]
Capacitor
30 MFD 400 V [17]

Pressure tank

Amtrol · Pressure tank

Amtrol Well-X-Trol WX-202

Product type
Pressure tank
Use case (derived)
Pressure tank
Supply voltage
not published
Flow
not published
Pressure
Max Working Pressure: 150 psig [1]
Speed control (derived)
not published
Tank Volume
20 gal [1]
Diameter
15 in [1]
Height
32 in [1]
System Connection
1 in NPTF [1]
Drawdown 30 50 Psig
6.2 gal [1]
Drawdown 40 60 Psig
5.4 gal [1]
Drawdown 50 70 Psig
4.7 gal [1]
Shipping Weight
32 lb [1]
Factory Precharge
38 psig [1]
Drawdown Note
Drawdown can be affected by various ambient and system conditions, including temperature and pressure. [1]
Warranty
Seven (7) year limited warranty [2]
Max Operating Temperature
200°F (93°C) [3]

Amtrol · Pressure tank

Amtrol Well-X-Trol WX-250

Product type
Pressure tank
Use case (derived)
Pressure tank
Supply voltage
not published
Flow
not published
Pressure
Max Working Pressure: 150 psig [1]
Speed control (derived)
not published
Tank Volume
44 gal [1]
Diameter
22 in [1]
Height
36 in [1]
System Connection
1-1/4 in NPTF [1]
Drawdown 30 50 Psig
13.6 gal [1]
Drawdown 40 60 Psig
11.8 gal [1]
Drawdown 50 70 Psig
10.4 gal [1]
Shipping Weight
65 lb [1]
Factory Precharge
38 psig [1]
Drawdown Note
Drawdown can be affected by various ambient and system conditions, including temperature and pressure. [1]
Warranty
Seven (7) year limited warranty [2]
Max Operating Temperature
200°F (93°C) [3]

Use case not published

VEVOR · Pump

Fixed speed

VEVOR UDPm100-1

Product type
Pump
Use case (derived)
not published
Supply voltage
AC 115V / 230V, 60Hz [22]
Flow
Max Flow: 1400 GPH [22]
Pressure
Max Head: 164 ft [22]
Speed control (derived)
Fixed speed [22]
Factory Voltage Preset
230 V [22]
Horsepower
1 HP [22]
Inlet Connection
NPT 1.0 in + 1.25 in [22]
Outlet Connection
NPT 1.0 in [22]
Pressure Switch
30-50 PSI; starts below 30 PSI and shuts off above 50 PSI [22]
Operating Temperature
32 to 104 °F [22]

How a filter reads the dataset

  • Use case is derived. It is not a column. A published application spec is read first: “R.O. Boost” or reverse osmosis means RO; “Pressure Cleaner Booster Pump” or a pressure-side pool cleaner means pool cleaner; “whole-house” means whole-house. If that field is missing or does not name a use case, the other published fields are used. Pressure tank means product_type is pressure_tank. RO means compatible_ro_systems is published. RV / 12V means the only supply voltage is 12 V. Pool cleaner means the manufacturer is Polaris. Whole-house means none of those, there is no pressure_switch spec, and the record publishes at least 8 GPM or at least 80 ft of head. Anything else is not published.
  • Supply voltage is the voltage or supply_voltage spec, read as 12 V, 24 V, 115 V, or 220–240 V. A dual-voltage spec matches each voltage it names.
  • Flow is the first published of max_flow, nominal_flow, open_flow, or flow_rate, compared in GPM. GPH is divided by 60. LPM is divided by 3.785411784. Cubic metres per hour are multiplied by 4.402867539.
  • Pressure is the first published of nominal pressure, shutoff pressure, pressure setting range, minimum outlet pressure, max head, shutoff head, head, or max working pressure, compared in PSI. A range matches when it overlaps the filter. Feet of head are divided by 2.31.
  • Speed control is constant pressure when a pressure setting range is published, or the spec text says constant pressure, variable speed, or VFD. It is fixed speed when a pressure switch is published, one RPM is published, or the text says fixed speed. Otherwise it is not published. This dataset does not print the letters VFD.
  • An upside-down range, with the minimum above the maximum, is not applied.

Sources

  1. Next Generation Well Tanks specifications, MC7025 (03/26) (retrieved 2026-11-24)
  2. Well-X-Trol residential pre-pressurized well tanks installation manual, models WX-101 through WX-350, 9015-868 MC10185 (07/25) (retrieved 2026-11-24)
  3. Submittal data MC4400 (08/25), Diaphragm Well Tanks: WX-100, 200 and 300 Series (retrieved 2026-11-24)
  4. SMART45 manual, Permanent Magnet Pump, AQUASTRONG Co., Ltd. (linked from the aquastrong.co product page) (retrieved 2026-11-24)
  5. Smart45 Automatic Water Pressure Booster Pump for Home, 115V (retrieved 2026-11-24)
  6. Series 8800 Pump Model: 88XX-2X03-B424 (retrieved 2026-11-24)
  7. ESYBOX MINI 3 electronic pressure boosting system technical data, 50260015, 03/2026 (retrieved 2026-11-24)
  8. Davey BT Series with Torrium2 datasheet (retrieved 2026-11-24)
  9. BT Series Mains Boosting Pump with Torrium2 (retrieved 2026-11-24)
  10. 93381101 – FE-VBPRO-115 (retrieved 2026-11-24)
  11. VersaBoost Pro (retrieved 2026-11-24)
  12. GRUNDFOS SCALA1, 1125_DN001481, Grundfos Holding A/S 12.2025 (retrieved 2026-11-24)
  13. GRUNDFOS SCALA2 integrated water boosting pump, DN001466, Grundfos Holding A/S 10.2025 (retrieved 2026-11-24)
  14. SCALA2 installation and operating instructions, 93058725, 03.2024 (retrieved 2026-11-24)
  15. iSpring PMP5 Booster Pump for 75 GPD, 100 GPD Reverse Osmosis Water Filter System (retrieved 2026-11-24)
  16. H0399500 REV F, Polaris PB4-60 Pressure Cleaner Booster Pump Installation and Operation Manual (Zodiac Pool Systems) (retrieved 2026-11-24)
  17. H0544300 REV C, Polaris PB4SQ Pressure Cleaner Booster Pump Installation and Operation Manual (Zodiac Pool Systems) (retrieved 2026-11-24)
  18. Variable speed fresh water pump product technical data sheet, aftermarket 55AQUAJET-ARV (retrieved 2026-11-24)
  19. Aquajet series flyer (retrieved 2026-11-24)
  20. 55 Series Automatic Demand Diaphragm Pump (retrieved 2026-11-24)
  21. SHURFLO REVOLUTION 4008 SERIES PUMP, RV fresh water pump product technical data sheet, 4008-101-A65 [E65] Rev. 04/16 (retrieved 2026-11-24)
  22. VEVOR 1 HP Shallow Well Jet Pump, model UDPm100-1 (retrieved 2026-11-24)